John Concrane November 5, 2019

Looking to buy high quality flexible metal conduit? Here are some tips and extra details helping you to make the best choice.

The ID and OD means inner diameter and outer diamter of flexible conduit. OD is the maximum of flexible conduit, and is a fixed number that can not be deviated from. Flexible conduit are always corrugated inner and outer, so we’d better leave more space inner to make wires and cables easier to through. So we should leave 20% space based on inner diameter. It may sound backward but use the diameter of the conduit as a guide to the service needed. It is better to use a conduit that is too big than one that is too small.

Thin-wall conduit is sold in ten-foot lengths in either one-half inch or three-quarter inch (outside) diameter. The one-half inch conduit can contain four No. 14 wires or three No. 12 wires. Three-quarter inch conduit accommodates four No. 10 or five No. 12 wires. These wire capacities are for individual wires, not pairs. The wires used are the same as the individual conductors found in steel armor cable and plastic sheathed cable. Wires in conduit must follow standard coding. In a two-wire electrical circuit you need one black wire, one white wire, and one ground wire. Read more details on Corrugated Conduit.

RMC and IMC can be used interchangeably, with IMC more common these days because it’s lighter and somewhat easier to work with than RMC. They are permitted for use by the NEC in dry, wet and corrosive locations and can be buried in many applications. They typically are joined with threaded connectors and fittings.

Flexible metallic conduit (also known as FMC) can be a practical choice for the large construction projects, for example building the underground car park. This particular conduit relies on interlocking metal coils to produce a long tube that lets the wires move through. By interlocking the individual pieces it can be possible to make a very flexible material. It really is practical to the installation protects that take place in a dry environment, but needs to be avoided if you have a risk of the water penetration.

Intermediate metal conduit, or IMC, is a thinner, lighter-weight version of rigid metal conduit and is approved for use in all of the same applications as RMC. Because IMC is lighter and easier to work with than RMC, it is more common in new construction. Another example of a rigid electrical conduit is EMT (electrical metal tubing), which is most commonly made of galvanized steel but can also be aluminum. EMT is also called “thin-wall” conduit because it is thin and lightweight, especially compared to RMC. EMT is rigid but can be bent with a simple tool called a conduit bender.

CorrugatedConduit.com is a leading supplier of flexible conduit located in Kowloon, China. We have 15 years cooperating qualified manufacturer in mainland. Because of our good quality control management and large volume we are able to sell you the best flexible conduit at competitive prices. Source: https://corrugatedconduit.com/.