Marian Vasilescu November 15, 2020

Eds testing and elemental mapping services in US? Problem: A client was a manufacturer of beverages, bottled water, and other drinks. They received a customer complaint through one of their distributors, which indicated that a customer had been drinking a bottle of water, and as they neared the bottom of the bottle, found a mysterious white powder floating in the bottom. The customer returned the bottle and complained. The client hoped to identify the powder so they could both satisfy their end customer, as well as identify any potential problems in their manufacturing or bottling process.

Our membrane autopsy service uses a combination of microscopy techniques to examine filtration membranes and identify the elemental and chemical composition of any foulant materials present. This analysis also categorizes the degree of fouling and notes any other causes for poor performance, such as physical damage to the membrane surface. MicroVision Labs has extensive experience examining a wide variety of RO, UF and MF membranes, including hollow fibers, cartridge, spiral wound, and tubular membranes.

How do I submit a sample or a set of samples? To submit a sample or set of samples, please see the page How to Submit Samples. What if I believe my samples are hazardous? We are not equipped to handle or dispose of every kind of hazardous material. Please call us before sending in any potentially hazardous samples. In cases where we are able to analyze your harzardous samples we may not be able to dispose of them and therefore we will return them to you. See a few extra details at more on this.

A device manufacturer had a product that involved a few different boards with varying components. There were circumstances that caused the need for a change in manufacturers of one of the boards. Due to this change, the device production at this facility would be shut down until the boards from this new vendor were validated. The Quality Control department required that an inspection of the solder joints of some of the components on the board be analyzed in order to determine whether this new board manufacturer met their specifications. If the desired specifications were met and no issues were found during the inspection of the joints then production of the devices could resume.

MicroVision Laboratories, Inc. has been providing businesses, consultants and other testing laboratories with expert microscopy and analytical services since 2003. Our client base covers a broad spectrum of industries including semi-conductors, aerospace, electronics, biomedical, ceramics, optics, pharmaceuticals, mineralogy, metallurgy, thin films, environmental, membranes filtration and industrial hygiene.

An affected floor tile was submitted to determine if the previous mold testing had missed a source on the tile backing or mastic. Additionally, a new tile from the same manufacturing lot was submitted for comparison. The process of preparing and examining the sample and reference tile was documented. Areas with darkened surface features were imaged and then cut out and examined. While the dark spots looked very discrete when examined by eye, under top light polarized microscopy they appeared more diffuse at the outer edges. The darkest areas surrounded what appeared to be particles embedded in the surface. Discover extra details on https://microvisionlabs.com/.